MAInTenAnCe
Before accessing live electrical parts, disconnect the
power supply to the dryer using disconnect switch or
disconnect the cable connections.
Preventive maintenance
For optimum performance from your dryer, follow the
periodic maintenance schedule described below.
weeKLY
COnDenSATe DRAInS
Verify that the condensate drains
are operating correctly.
eVeRY 4 MOnTHS COnDenSeR
Remove any dust from the con-
denser fins.
COMPReSSOR
Make sure compressor power
consumption complies with data
plate specifications.
YeARLY
COnDenSATe DRAInS
Completely disassemble the
drains and clean all their compo-
nents.
AIR FILTeR
Replace air filter element.

MOISTURe SePARATOR MAInTenAnCe

The moisture separator will operate indefinitely under
normal working conditions, however at some time
it may be necessary to replace the seals should the
housing leak.
1.
Isolate the housing from the air supply.
2.
Fully depressurize in drain bowl as appropriate.
.
Unscrew bowl and remove. If pressure has not
been completely released from the housing,
air will escape from the warning hole giving
an audible alarm. Screw back bowl and repeat
instruction 2 before attempting again. Should
resistance to unscrewing be experienced,
provision is made for a 'C' spanner to fit onto the
ribs of the bowl.
.
Check condition of bowl seal and replace if
necessary. Clean screw threads.
5.
Refit bowl with 'O' ring seal.
.
Repressurize and check for leaks. If leaks occur
they will most probably be from the bowl 'O'
ring. Depressurize housing and remove 'O' ring as
stated above and inspect and clean. Ensure that
mating surfaces are clean and then refit 'O' ring
and repressurize.

OPeRATIOn AnD MAInTenAnCe MAnUAL

AIR FILTeR MAInTenAnCe

In order to ensure optimum compressed air quality the
filter element should be replaced as follows. (Used filter
elements must be disposed of in accordance with local
regulations.)
Use only genuine Ingersoll Rand replacement
elements.
2
1
3
> 30s
4
2
1
0 bar
5
7
9
2
1
12
1
2
5
0 psi
6
1
8
0 bar
0 psi
10
0 bar
0 psi
2
http://air.ingersollrand.com
0 bar
0 psi
0 bar
0 psi

Publicité

Table des Matières
loading

Table des Matières