Noted below are general maintenance guidelines, which must be followed and documented, this in accordance
with the Ingersoll Rand Warranty. It is based on an approximate Compressor usage of 30 hours per week. If your
particular application varies from this, please adjust accordingly.
When servicing the Air Compressor, shut off all power to the Unit, and drain the Tank
of air pressure. Always re-install the Beltguard after adjusting the Belts or Pulleys.
Insist on Genuine
Ingersoll Rand parts and
kits when maintaining
your Compressor Unit
and Pump.
Drain moisture from Air Receiver
Check oil level and top up as required
Clean Air Filter
Check Belt Tension
Check Safety Valves
Check that Unit unloads when shutting down
Clean and/or blow dust/dirt off Unit
Replace Air Filter
Replace Oil (synthetic)
Check lubrication of Motor
Inspect Valve Assemblies in Cylinder Head(s)
Replace Check Valve
Inspect Pressure Gauge
Replace Belts
Replace Valve Discs and Springs
Replace CPR Unloader Kit
Replace Pressure Switch
Replace Safety Valves on Pump and Tank
Replace Pressure Gauge
Notes:
1. Air Filters are available separately or in a Maintenance Kit. Consult your Pump bulletin.
2. Synthetic Oil is available separately or in a Maintenance Kit. Consult your Pump bulletin.
3. Belts are available through your local Ingersoll Rand Distributor.
4. Valve Discs and Springs are available separately or in a Kit. Consult your Pump bulletin.
5. The CPR Unloader Assembly and Kit is noted in your Pump bulletin.