Start-Up Procedures; Initial Start-Up - Ingersoll Rand PL-MANW Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Initial Start-up

1) Remove the Oil Filler Plug and ensure that there
is sufficient Oil in the Crankcase. Refer to the
'Lubrication' section (Page 6) in this manual for
6
proper type and level of Oil.
2) Replace the Oil Filler Plug and use a
crescent wrench to tighten snug plus 1/4 turn.
3) Do a visual inspection of the Unit and ensure that
all Bolt heads are sufficiently tightened. This must
be done, as some fasteners may become loose
in transit.
4) Turn the Compressor 'On' momentarily by
positioning the Fused Disconnect or Breaker in
the 'On' position. Ensure that the Flywheel is
turning in the correct direction. See the 'Pump
Rotation' (Page 8).
On Compressors with 3 phase power, switch
'L1' and 'L3' at the input into the Magnetic
Starter if the rotation is incorrect.
5) Open the Compressor's Ball Valve and start the
Unit. Ensure that air is escaping to atmosphere.
Allow the Unit to operate in this fashion for 5
minutes. This lubricates the Pistons, Bearings,
and all internal surfaces.

Start-up Procedures

Do not attempt to operate the Unit without first checking
whether there is oil in the Pump. Add oil as required. Serious
damage may result from use, however limited, without oil.
6) After having run the Unit unloaded for 5 minutes,
7) Ensure that the Compressor shuts off at the
8) Measure the amp draw as the Unit reaches
9) Once off, check the Compressor and piping
During the first few days of operation, check the Unit
periodically to ensure it is running smoothly. Should you have
any concerns, contact your Ingersoll-Rand Distributor.
- 9 -
Do not place any materials near the
Compressor. Placing materials against or
close to the Unit will limit the cooling
required and could lead to premature failure.
close the Ball Valve, and allow the Unit to reach
maximum operating pressure.
factory preset maximum pressure, and the head
pressure is released through the Unloader at
either the front of the Pump (the 'CPR') or at the
Pressure Switch.
maximum pressure. It should not exceed the
motor amp.
systems for any air leaks. Correct as required.
Shut off all power to the Compressor Unit
before attempting any repair or maintenance.
PL-MANW
Rev.B, Nov'20