SCHeMATIC, eLeCTRICAL UP6 5–15HP FV 3PH 60Hz DOL – U.S.A.
KeY
1FU,
Fuse control circuit
2FU, FU
FU, 5FU Fuse
1Ma
Contact, auxiliary starter
1Mb
Contact, auxiliary starter
CPT
Transformer, control
120/1/50–0
See transformer nameplate for wiring
connection requirements
CR
Relay, control
CRa
Contact, control relay
CS
Customer supplied 115v / 1 / 0hz
DO
Dryer option
DM
Motor, dryer
EDV
Valve, electric drain 120/1/50–0
E-STOP
Button, emergency stop
G
Power on light
HM
Hourmeter
HM1
Indicator, maintenance
http://air.ingersollrand.com
HATS Switch, high air temperature
M
Coil motor starter
MIO
Indicator, maintenance option
(Instead of standard hourmeter)
MOT Motor
OL
Overload, motor starter
PS
Switch, pressure
ST
Push button, start
TP
Terminal points
TS
To supply
W
Standby light
nOTeS
1.
(*) Furnished, mounted and wired outside of control
panel, if required by order.
2.
Circuit shown in normal position de–energized.
.
All wiring to be marked in accordance with this
schematic.
.
All wiring to be in accordance with NEC.
GeneRAL InFORMATIOn