12.8 Mounting the idler bush (37 fig. 10)
Clean the seat in the idler thoroughly.
The idler bush must be mounted using a press. It is perfectly symmetrical and can therefore be mounted in either direction. When mounting
the bush in its seat, use a continuos movement. For the V 180 and V 200, heat the idler to 80 degrees C before mounting the bushes.
Wait until they have cooled completely and use machine tools to bring them to the tolerance indicated by Varisco (only for graphite bushes
version).
13

STORAGE

If the pump is to be stored for a certain period of time, it is advisable to empty and clean it. If necessary, wash with a suitable solvent.
Avoid using water.
Pour a little oil, fuel oil, or rust preventer into the pump, grease the bearing and turn the pump over a few times. If the pump is to be left out
in the open, close the ports and cover the pump with a waterproof canvas. Take care to leave holes for ventilation to avoid condensation.
14

SPARE PARTS

To order spare parts, specify the following:
- type of pump
- serial number of the pump
- reference number and description of the part as shown in the exploded drawing
15

DISPOSAL

- Do not abandon the pump, or any part of it, in the environment
- Metal parts can be recycled as scrap
- Grease and oil must be recovered and stored as prescribed by the relevant legislation for disposal by approved agencies
- Elastomer gaskets must be removed and disposed of in an approved waste disposal unit