Faq, Causes And Measures Uniroof St - Leister UNIROOF AT Mode D'emploi

Masquer les pouces Voir aussi pour UNIROOF AT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

15. Warning and error messages (UNIROOF ST)
Message type
Warning
16. FAQ, causes and measures (UNIROOF ST)
Defi cient quality welding result:
• Check drive speed, welding temperature and air volume.
• Clean welding nozzle (9) with wire brush.
• Welding nozzle (9) incorrectly adjusted (see Adjust welding nozzles).
After 5 minutes at the most, the set welding temperature has still not been reached:
• Check mains voltage.
• Reduce air volume.
Device does not move forward in a straight line:
• Align the track guide roller (16) so that it is parallel and linear to the drive/pressure roller (8)
(see welding sequence).
• Adjust the transport roller (13) to the movable transport axle (12) (see Set the movable transportation axle).
Display
Both LED −
Statuses, i.e. LED
Drive (31) status
and LED Heating
(34) status, are
fl ashing.
8
14
13
Error code
Error description
Network voltage
The air volume can no longer be adjusted.
16
75

Publicité

Table des Matières
loading

Table des Matières