1.1 Intended use
UNIROOF AT/ST is intended for professional use on fl at roofs and sloping roofs up to 30-degree angle of inclination.
Use only original Leister spare parts and accessories because otherwise no warranty or guarantee claims can be
asserted.
Welding processes and types of materials
• Overlap welding of thermoplastic sealing sheets/elastomer sealing sheets
(ECB, modifi ed EPDM, EVA, FPO, PIB, PMI, PO, PP, PVC, TPO)
• Overlap welding for base seams
• Edge-close welding on the roof parapet (parapet, eaves) up to 100 mm.
• Welding on the roof parapet (parapet, eaves).
• Welding widths (20, 30, 40 mm).

1.2 Non-intended use

Any other use or any use in excess of these is considered non-intended.

2. Technical data

We continue to reserve the right to make technical changes.
Nominal voltage
Nominal voltage
Frequency
Temperature
Air volume
Drive
Emission level
Dimensions (L × W × H)
Weight
Mark of conformity
Protection Class I
Nominal voltage
Nominal voltage
Frequency
Temperature, stepless
Air volume, stepless
Drive, stepless
Emission level
Dimensions (L × W × H)
Weight
Mark of conformity
Protection Class I
UNIROOF AT
100 V
V~
100
W
1500
Hz
°C
%
m/min.
L
(dB)
pA
mm
kg
UNIROOF ST
100 V
V~
100
W
1500
Hz
°C
m/min.
L
(dB)
pA
mm
kg
UNIROOF AT
120 V
120
1800
50 / 60
100 – 620
45 – 100
1 – 10
70 (K = 3 dB)
475 × 244 × 260
17.5 (including 3 weights)
UNIROOF ST
120 V
120
1800
50 / 60
100 – 620
1 – 10
0.7 – 10
70 (K = 3 dB)
475 × 244 × 260
17.5 (including 3 weights)
UNIROOF AT
220 – 240 V
230
3450
UNIROOF ST
220 – 240 V
230
3450