Warnings and error messages

• If there is a warning pending, the user can continue to work. You can access more detailed information about the
warning via the function display (33) by selecting "Show Warnings" in the Settings menu.
• If a warning occurs while welding, this can be displayed with the "Up" key
• If an error occurs, the heating is switched off and the drive is no longer released.
• If the drive is blocked, switch off the main switch (2) and disconnect the power cord (1) from the mains. Contact
a Leister service center.
Type of
Display
message
Warning
Error
Error
Error*
*Contact Leister Service Center
Error code/
warning message
Heat Cartridge Broken
Ambient Temperature
Undervoltage
Overvoltage
Max. Force Exceeded
Drive Overcurrent
0001.XXXX
0002.XXXX
0004.XXXX
0008.XXXX
0020.XXXX
0200.XXXX
0400.XXXX
.
Error description
A heating cartridge is defective
Ambient temperature is too high
Undervoltage
Overvoltage
Max. clamping force exceeded
Current limitation
Device has overheated.
Allow the device to cool down.
Overvoltage or undervoltage of the mains voltage.
Check voltage source.
Hardware error
Thermocouple is defective
Heating cartridge is defective
Communication error
Drive error