1. Work Mode

1.9 Standby

• If the welding nozzle (9) is not in the welding position and no button is pressed du-
ring a standby time defined by the user, Cool Down mode will automatically start after
the countdown has passed (Fig. 20).
The cooling down process is initiated.
• If the e-Drive
display (5) will change to Work Display (see Section 1.2 Work Display).
• Setting the standby time (Section 2.3 Standby Setup).

1.10 Error messages

• If a malfunction occurs in the hot air welding
machine VARIANT T1, a message accompanied
by an error code will appear on the display (5).
This code stands for a more precise definition of
the error which can be seen in the list below.
• Separate symbols are displayed for error 02
and error 40.
• In case of all other errors, the spanner is dis-
played for the service prompt.
Error
Type of error
Err00
Control electronics defective
Err01
Interruption or short-circuit of the temperature probe
Err02
Heating element / Electronics defective (interruption in one/both winding(s))
Err04
Triac defective (one or both Triacs are defective)
Err08
Blower motor defective
Err40
Undervoltage 25% (mains voltage 75%) only VARIANT T1 230 V~
2. Profile Setup

2.1 Profile Setup Button Combination

Keep Drive and Heating buttons pressed
with main switch ON at the same time.
is pressed before the countdown has passed (180 seconds), the
ON
Release
(Fig. 20)
1
2
3
37