6.3

SMOKE EXHAUST SYSTEM

The Ecomonoblocco must be connected to a smoke
exhaust system so as to ensure combustion products are
suitably discharged into the atmosphere, in accordance
with standards EN 1856-1-2 EN 1857, EN 1443 EN
13384-1-3, EN 12391-1 and UNI 10683, both as regards
sizing and the construction materials used.
• CHIMNEY draught must be sized as described on
the datasheet.
• The components making up the combustion
product exhaust system must be declared as being
marked (declaration of conformity or European
technical approval for the product).
• The ue must have a constant cross-section along
its entire height.
• A c o l l e c t i o n c h a m b e r s h o u l d b e f e a t u r e d
a t t h e b o t t o m o f t h e f l u e t o c o l l e c t
any solid residues and condensate.
IMPROVISED ues made using unsuitable materials
are illegal and affect correct operation of the
Ecomonoblocco.
• A PERFECT DRAUGHT is above all the result of
a ue that is clear of obstructions such as chokes,
horizontal sections or corners; any axial displacements
should be at a maximum angle of 45° compared to
the vertical axis, (better still if it is only 30°). These
displacements should preferably be effected near the
chimney top (Fig. 6.5).
• The SMOKE connection between the replace and
flue should have the same cross section as the
stove's smoke outlet. The smoke tting must be sealed
and the use of exible metallic pipes is prohibited.
Changes in direction in respect to the smoke outlet
of the appliance must be executed using elbows not
exceeding 45° in respect to vertical.
• The CHIMNEY TOP shall be the WINDPROOF type
with an inside cross section equivalent to that of the
ue and with a smoke outlet passage section at least
DOUBLE the internal one of the ue.
• To avoid draught problems, each stove should have
its own ue. If there is more than one ue on the roof
the others should be situated at a distance of at least 2
metres and the stove's chimney top should be at least
40 cm ABOVE the others (Fig. 6.4). If the chimney
tops are near each other install some dividing panels.
• Fig. 6.6 (FLAT ROOF; B service compartment) and
Fig. 6.7 (SLOPING ROOF; B above the ridge) show
suggestions on the minimum distances and chimney
top positions.
• If the stove is installed with a ue that has already
been used it should be cleaned thoroughly to avoid
malfunctions and the danger of unburned parts
deposited on the inside from catching re.
• Under normal conditions of use of the stove the ue
should be cleaned at least once a year or after 40
quintals of wood have been burnt, unless regulations
state otherwise except for different regulations.
> 5 m
> A
α
C
ONSIGLI
Recommendations - Beratung
C
,
OMIGNOLI
DISTANZE E POSIZIONAMENTO
Chimney tops, distances and positioning;Schornsteine, Abstände und Positionierung
Inclinazione del tetto
Distanza colmo-camino
Roof slant
Distance ridge cap-chimney
Neigung des Dachs
Abstand Dach rst und Kamin
A[m]
< 1,85
15°
> 1,85
< 1,5
30°
> 1,5
< 1,3
45°
> 1,3
< 1,2
60°
> 1,2
- 6.5 -
≤ 5 m
B
- 6.6 -
≤ A
H min
0,50 m
- 6.7 -
:
altezza min del camino (dallo
sbocco)
minimum chimney height
Mindesthöhe des Kamins
H[m]
0,5 oltre il colmo; above the ridge of
the roof; über den Dach rst
1 dal tetto; from the roof; vom Dach
0,5 oltre il colmo; above the ridge of
the roof; über den Dach rst
1,3 dal tetto; from the roof; vom
Dach
0,5 oltre il colmo; above the ridge of
the roof; über den Dach rst
2 dal tetto; from the roof ; vom
Dach
0,5 oltre il colmo; above the ridge of
the roof; über den Dach rst
2,6 dal tetto; from the roof; vom
Dach