5 PREPARING
THE PLACE OF
INSTALLATION
5.1

SAFETY PRECAUTIONS

The instructions below are however subject to national
and local laws and regulations in force in the country in
which the product is installed.
The user is responsible for the work carried out in the
area where the replace is installed; the user is likewise
responsible for checking the various installation solutions
proposed.
The user must comply with all the local, national and
European rules and regulations.
If the floor does not have a sufficient load-bearing
capacity, it is advisable to use a load-distributing plate
of an appropriate size.
The appliance must be installed on a floor with an
adequate carrying capacity
The stove assembly and disassembly operations must
be carried out by skilled technicians only.
The quali cations and effective expertise of such skilled
technicians should be veri ed.
Before starting the assembly or dismantling phases of
the machine, the installer must comply with the safety
precautions as established by law, and in particular as
regards:
A) he must not work in adverse conditions;
B) he must be in perfect psychophysical condition to
work and ensure that the individual and personal
accident prevention devices are sound and in perfect
working order;
C) he must wear accident prevention gloves;
D) he must wear safety shoes;
E) he must make sure that the area he is working in
for assembling dismantling the stove is free from
obstacles.
Floors made of ammable materials around replaces
must be protected with non-flammable material as
follows: in the front, equal to the height above the oor of
the re compartment base or the redog plus 30 cm (but
at least 50 cm), on the sides, equal to the height above
the oor of the re compartment base or the redog plus
20 cm (but at least 30 cm). With an upright grid of at least
10 cm height, re protection of 50 cm in the front and 30
cm on the sides is suf cient.
The non- ammable covering may be made of ceramics
(e.g. tiles), natural stone or other mineral materials (e.g.
marble, granite), of at least 1 mm thick metal or of suitably
load-bearing glass. The covering must be secured
against shifting, i.e. fastened.
5.1.1
A spark protection apron is required (e.g. to cover
carpets, parquet ); a reproof oor covering made of
non- ammable material
(natural stone ) must be put in place.
5.2

PRELIMINARY OPERATIONS

• The adjustable feet are secured to the appliance for
transport purposes.
• Before removing the counterweight stop screws
(safety lock for transport on models equipped with
sliding door), carefully place the appliance on its back
to screw in the adjustable feet.
• Should it be required, secure the air tting, separated
by means of the clamp supplied, to the ame, in the
desired position.
• It is absolutely mandatory to plumb the monoblocco!
• The monoblocco can be connected with the horizontal
outlet by rotating the exhaust dome. To do so open
the clamp, position the exhaust dome and secure it
with the clamp.
5.3

DRY POSITIONING

It is advisable to pre-assemble the replace dry
so as to understand how much space the various
components and air intake passageways take up.
• It is necessary to match the front part of the unit with
the inside edge of the marble slab, leaving a 5 mm slot
so as to allow for free dilation of the Ecomonoblocco.
5.3.1

Safety recommendations

The cladding of the fireplace, regardless of the
material used, must be self-bearing with respect to the
Ecomonoblocco and it must not be in contact with it.
Any wood beams, or any finishing in combustible
material, must be suitably insulated (or placed outside
the area of radiation of the replace), and must be at a
distance form the Ecomonoblocco of at least 2 cm ( g.
6.1) to guarantee free air ow to avoid overheating.
Any coverings in combustible material located over
the generator must be shielded by diaphragms in non-
combustible insulating material.