Error codes
H0 - Fig. 107
Wheel running conditions cannot be improved by optimisation.
H1 - Fig. 108
Further optimisation not recommended but feasible.
H2 - Fig. 109
Weight minimisation is recommended, optimisation can
achieve no further improvement.
H3 - Fig. 110
Optimisation not recommanded.
H20 - Fig. 111
Correction plane cannot be re-located with the geodata gauge
arm for distance and rim diameter.
Measure the correction plane and switch to dynamic
D
unbalance reading.
H21 - Bild 112
The indexed position is not the one for the correction plane in
which the adhesive weight is to be fitted with the geodata gauge
arm.
Index the correct position for this correction plane prior to
D
fitting the adhesive weight.
Operation manual geodyna 6300 - 9512 152
H0 - Fig. 107
Impossible d'améliorer la stabilité de marche de la roue au
moyen d'une optimisation.
H1 - Fig. 108
Déconseillé de continuer l'optimisation qui reste pourtant pos-
sible.
H2 - Fig. 109
Recommandé de minimiser la masse; continuer à optimiser
n'apporte pas d'amélioration.
H3 - Fig. 110
Optimisation non recommandée.
H20 - Fig. 111
Le plan de correction ne peut pas être retrouvé avec la pige de
mesure geodata pour écart et diamètre de jante.
Mesurer le plan de correction et vérifier que le balourd
D
dynamique soit affiché.
H21 - Fig. 112
La position d'orientation ne correspond pas au plan de correc-
tion sur lequel la masse adhésive doit être placée à l'aide de la
pige de mesure geodata.
Pour placer la masse adhésive, orienter le plan de cor-
D
rection adéquat.
Mode d'emploi geodyna 6300 - 9512 152