General Notes; Gas Safety Regulations (For Installation & Use) 1998; Cleaning And Maintenance; Discoloration Of Walls And Ceiling - Dru SCENIC Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING INSTRUCTIONS
Changing the code
The remote control code can be
changed if so required.This will require
changing the DIP SWITCH, which is on
the remote control near the battery.
Once the code has been changed,
press the reset button on the receiver
until you hear two signals. After the
second, longer signal release the reset button and within
20 seconds press
on the remote control until you hear
an extra long signal.This means that the new code has
been confirmed.

GENERAL NOTES

Gas Safety Regulations (for installation & use) 1998
In your own interest and that of safety, it is law that all gas
appliances are installed by competent persons in
accordance with the above regulations. Failure to install
appliances correctly could lead to prosecution.
NB: The Council of Registered Gas Installers, whose
members are identified by the emblem shown here, are all
required to work to the recognised standards.

Cleaning and Maintenance

The appliance should be inspected once a year by a qualified
company, and cleaned and/or repaired as necessary.The
inspection and maintenance must at least ensure that the
appliance is working correctly and safely.This can be done
by your own gasinstaller or a specialised maintenance
company. It is advisable to remove any dust from the
appliance several times before and during the heating
season. After a while a deposit will form on the inside of the
glass pane.This can be removed with a damp cloth or with
a non-abrasive cleaning agent (e.g. brass polish). Do this as
soon as any deposit appears, to prevent it from burning and
becoming impossible to clean. Do not use corrosive or
abrasive substances to clean the casing. Any damage to the
coating, caused by things put on or against the casing for
example, is not covered by the guarantee.
NB: When replacing the thermocouple, the coupling nut in
the gas control block should first be tightened by hand and
then tightened a quarter-turn with an
open-ended spanner.

Discoloration of walls and ceiling

Brown discoloration is an annoying problem, which is
difficult to solve. It can be caused by dust burning as a
result of poor ventilation, for example, or by cigarette
smoke or candles.
These problems can be avoided by ensuring that the room
the heater is in is properly ventilated. A good guideline for
ventilation is:
New buildings
: 3.24 m
surface of the room.
Existing buildings
: 25.20 m
Use candles and oil lamps as little as possible, keeping the
wick as short as possible.While they Enhance the
atmosphere, candles and oil lamps also cause the
formation of large quantities of unhealthy soot particles in
your home. Cigarette and cigar smoke contains tar, which
upon heating will precipitate on cold or damp walls. If you
have a newly cemented chimney or have had any other
reconstructions / renovations done, you are advised to
wait at least 6 weeks before lighting your fire, to allow the
walls, floor and ceiling to dry out completely.
GENERAL NOTES
3
/ hour per m
2
floor
3
/ hour for a room.