GENERAL NOTES

1. Thermostat button + push button control the gas
supply to the pilot light
2. Piezo
3. Manual control
1.
3.
N.B.: If the flue spillage sensor is repeatedly activated, a
qualified gas installer should be contacted.
GENERAL NOTES
Gas Safety Regulations (for installation & use) 1998
In your own interest and that of safety, it is law that
all gas appliances are installed by competent persons in
accordance with the above regulations. Failure to install
appliances correctly could lead to prosecution.
NB: The Council of Registered Gas Installers, whose
members are identified by the emblem shown here,
are all required to work to the recognised standards.
2.

Cleaning and Maintenance

The appliance should be inspected once a year by a
qualified company, and cleaned and/or repaired as
necessary.The inspection and maintenance must at least
ensure that the appliance is working correctly and safely.
This can be done by your own gasinstaller or a specialised
maintenance company. It is advisable to remove any dust
from the appliance several times before and during the
heating season. After a while a deposit will form on the
inside of the glass pane.This can be removed with a damp
cloth or with a non-abrasive cleaning agent (e.g. brass
polish). Do this as soon as any deposit appears, to prevent
it from burning and becoming impossible to clean. Do not
use corrosive or abrasive substances to clean the casing.
Any damage to the coating, caused by things put on or
against the casing for example, is not covered by the
guarantee.
The chimney should be inspected regularly, to check
that all flue gasses are discharged through the chimney.
Excessive accumulation of soot in the chimney should be
avoided. The soot that does form should be removed,
only ever when cold, with a brush or vacuum cleaner. The
ventilation should also be checked regularly, to make sure
there are no obstructions.
NB: When replacing the thermocouple, the coupling nut
in the gas control block should first be tightened by
hand and then tightened a quarter-turn with an open-
ended spanner.
ûDiscoloration of walls and ceiling
Brown discoloration is an annoying problem, which is
difficult to solve. It can be caused by dust burning as a
result of poor ventilation, for example, or by cigarette
smoke or candles.
These problems can be avoided by ensuring that the room
the heater is in is properly ventilated. A good guideline for
ventilation is:
New buildings
Existing buildings
22
: 3.24 m
/ hour per m
floor
3
2
surface of the room.
: 25.20 m
3
/ hour for a room.

Publicité