1.Thermostat button + push button control the gas supply
to the pilot light
2. Piezo
3. Manual control
1.
3.

GENERAL NOTES

Gas Safety Regulations (for installation & use) 1998
In your own interest and that of safety, it is law that all gas
appliances are installed by competent persons in
accordance with the above regulations. Failure to install
appliances correctly could lead to prosecution.
NB: The Council of Registered Gas Installers, whose
members are identified by the emblem shown here, are all
required to work to the recognised standards.
Cleaning and Maintenance
The appliance should be inspected once a year by a
qualified company, and cleaned and/or repaired as
necessary.The inspection and maintenance must at least
ensure that the appliance is working correctly and safely.
This can be done by your own gasinstaller or a specialised
maintenance company. It is advisable to remove any dust
from the appliance several times before and during the
heating season. After a while a deposit will form on the
inside of the glass pane.This can be removed with a damp
cloth or with a non-abrasive cleaning agent (e.g. brass
polish). Do this as soon as any deposit appears, to prevent
it from burning and becoming impossible to clean. Do not
use corrosive or abrasive substances to clean the casing.
Any damage to the coating, caused by things put on or
against the casing for example, is not covered by the
guarantee.
The chimney should be inspected regularly, to check that
all flue gasses are discharged through the chimney.
Excessive accumulation of soot in the chimney should be
avoided.The soot that does form should be removed, only
ever when cold, with a brush or vacuum cleaner.The
ventilation should also be checked regularly, to make sure
there are no obstructions.
NB: When replacing the thermocouple, the coupling nut in
the gas control block should first be tightened by hand and
then tightened a quarter-turn with an open-ended spanner.

Discoloration of walls and ceiling

Brown discoloration is an annoying problem, which is
difficult to solve. It can be caused by dust burning as a
result of poor ventilation, for example, or by cigarette
smoke or candles.
These problems can be avoided by ensuring that the room
2.
the heater is in is properly ventilated. A good guideline for
ventilation is:
New buildings
Existing buildings
Use candles and oil lamps as little as possible, keeping the
wick as short as possible.While they Enhance the
atmosphere, candles and oil lamps also cause the
formation of large quantities of unhealthy soot particles in
your home. Cigarette and cigar smoke contains tar, which
upon heating will precipitate on cold or damp walls. If you
have a newly cemented chimney or have had any other
reconstructions / renovations done, you are advised to
GENERAL NOTES
: 3.24 m
3
/ hour per m
2
floor
surface of the room.
: 25.20 m
3
/ hour for a room.