5.

Unused Battery Mode

The quick test "Unused battery mode" enables you to
check new batteries. With this quick test, up to 100
batteries can be checked in a row. Unlike the battery
test, this test indicates the results "
Good recharge
Make complaint
"
" or "
i
Neither decision will tell you that a battery is bad, but
rather that the measured voltage and CCA fall in or out
of your requirements.
1. Select UNUSED BAT. MODE from the Main Menu and
press E.
2. Select ON and press E.
3. The tester displays the total number of Inventory Tests
completed out of 100. Select Clear Memory to clear
the results from memory and reset the total to 0 or
select Add To Memory to add the results to memory.
!
Be sure to monitor the number of tests performed
and be ready to print the results as the number
approaches 100. When the limit is reached you will
no longer be able to test until you clear all results
from memory.
4. Press E to continue.
5. BATTERY STANDARD
Select NORMAL, EFB, AGM (GLASS MAT), AGM
SPIRAL or GEL.
i
With EFB BAT technology, select the battery value
afterwards.
6. BATTERY TYPE
Select the battery standard to be applied.
Standard Description
EN
Europa-Norm
EN2
Europa-Norm 2
DIN
Deutsche Industrie-Norm
SAE
Society of Automotive Engineers,
the European labeling of CCA
IEC
International Electrotechnical
Commission
JIS
Japanese Industrial Standard,
shown on a battery as a
combination of numbers and
letters.
i
For JIS scroll to the correct BATTERY NUMBER and
press E to begin the testing process.
|
1 689 989 131
2019-03-02
7. BATTERY RATING
Battery good
",
".
Fig. 5:
i
8. Remove the battery connection cable and connect it
i
Range
100 – 2000
100 – 2000
100 – 1200
100 – 2000
100 – 1200
26A17 – 245H52
Select the battery value of the battery to be tested.
Keep  or  pressed to scroll faster.
 Press E to start the quick test. After a few sec-
onds, the condition of the battery and the volt-
age measured will be indicated on the display.
BAT 131 also indicates the selected battery value
and the battery standard.
Example for a result
In the results screen, the battery connection cable
can be removed and immediately connected to the
next battery. The next quick test will then be carried
out immediately. That way, several batteries can be
tested in quick succession.
to the next battery.
 The quick test will be started automatically and
the next result will be shown after a few seconds.
Press  to print the test results or  to return to the
Menu.