Performance processing consists in supervising the following monitoring ports:
for local equipment:
!
regeneration section (byte B1) ("near end working (protection) RS"),
!
multiplex section (byte B2) ("near end working (protection) MS"),
!
VC4 tributary paths ("near end High Path Virtual Container"),
!
VC3 tributary paths ("near end Low Path Virtual Container"),
!
VC12 tributary paths (byte V5) ("near end Low Path Virtual Container"),
for the remote equipment:
!
multiplex section (byte M1) ("far end working (protection) MS"),
!
VC4 tributary paths ("far end High Path Virtual Container")
!
VC3 tributary paths ("far end Low Path Virtual Container")
!
VC12 tributary paths (byte V5) ("far end Low Path Virtual Container").
Performance processing includes the following functions:
!
calculation of the number of errored blocks (or bit errors) on local and remote faults and
monitoring of the appearance faults over a one second period,
!
calculation and determination of the ES (Errored Second), SES (Severely Errored Second),
BBE (Background Block Error) and UAS (UnAvailable Second) states for each monitoring
point,
!
generation for each monitoring point of 15-minute counters and 24-hour counters (BBE, ES,
SES and UAS).
Determination of ES, SES and UAS performance states:
For each of the monitoring points, the following states are:
- ES (Errored Second)
- SES (Severely Errored Second)
An SES is a second for which the number of errors exceeds a defined threshold or
during which at least one fault is detected.
MS (byte B2) (for local) and MS (byte M1) (for remote)
RS (byte B1) (for local)
HP – VC4
LP - VC3 (for local)
LP - VC12 (byte V5) (for local)
- UAS (UnAvailable Second)
- BBE (Background Block Error)
No reproduction or communication without the written consent of SAGEM SA
: number of seconds with at least one error detected
in a 1 s period or one fault,
: number of severely errored seconds,
Monitoring point
: number of seconds of unavailability,
: number of residual errored blocks excluding SES.
SES declaration threshold
28800 (24 blocks per frame)
9600 (8 blocks per frame)
Installation and User Guide - N56717020104
2 - OPERATION
2400
2400
600
Page A2-19