2 - OPERATION
Configuration parameters per functional blocks
ADR FAN card
Fan operation mode selection
"Permanent cooling" :
Fan is ON, if T°> 5°C (41°F) , fan is OFF, if T° ≤0°C (32°F)
"Overhead Avoidance" :
Fan is ON, if T°> 35°C (95°F), fan is OFF, if T° ≤30°C (86°F)
Equipment
Session
Equipment Name
Selection of clearance level :
Administrator
Operator
Observer
One password by clearance level
(Only the administrator may modify password)
Authorization to transmit traps to the management:
"Traps Managers List"
Managers list
"Managers List" (10 addresses possible)
Authorised maximum clearance (exclusive choice)
Equipment date and time
Status of slots A, B, C, D
expected card configuration
Monitoring
Monitoring of modules
A no-monitored card is indicated in the equipment view; not monitoring a
card inhibits the entire management of the faults related to this card
(card and port)
Subrack Monitoring (Motherboard)
Monitoring of ports
Not monitoring a port inhibits the entire management of the faults and
performance related to this port
Putting a card into/out of service
(The card is ignored by the management function)
Installation and User Guide - N56717020104
Page A2-8
No reproduction or communication without the written consent of SAGEM SA
Table 2-7 – Configuration parameters (7/8)
Default
value
"Overhead
Avoidance"
Empty
Admin
No password
0.0.0.0
0.0.0.0
supervisor
"01/01/1970"
ADR Optical,
if absent card
Inserted card
if present
Monitoring
Monitoring
No Monitoring
for LPOM blocks
Monitoring
for others
Into Service,
if present card
Out of service,
if absent card