Configuration parameters per functional blocks
OHA : OverHead Access
EOW interface operating mode :
CO (codirectional) or CT (contra-directional master)
"EOW configuration"
Selection of byte used to convey order wire channel EOW in the SOH,
E1
E2
Line 7, bytes of columns 8, 9
Line 8, bytes of columns 8, 9
Line 9, bytes of columns 8, 9
AUX interface operating mode (F1);
CO (codirectional) or CT (contra-directional master)
"AUX configuration"
MNGT Port
Selection of MNGT interface operating mode
"Management Use" or
"Traffic (M#21)" (X24/V11 traffic data at 2048kbit/s)
MNGT port (allocated to management purposes)
MNGT port operating mode ;
CO (codirectional) or CT (contra-directional master)
"P port configuration"
MNGT port (allocated to traffic data)
Selection of physical interface port allocated to 21st motherboard access
for traffic
"G.703" ou "X24/V11"
In X24/V11 traffic mode:
Selection of "PPI X24 Clock Mode" of data received from DTE
"Far 2Mbs Clock" or
"SDH Subnetwork Clock"
Selection of "Data Sampling Edge" of data received from DTE
"Default Edge" or "Inversed Edge"
ADR E3DS3 Card
34 or 45 Mbit/s physical interface selection
"E3 (34M)" or "DS3 (45M)"
Connecting cable length selection so that transmitted pulse complies to
template defined in Bellcore GR-489-CORE standard : "Type of cable"
(DS3/45Mbit/s mode only
"long" or "short" (length < 225 ft or 70m)
Table 2-6 – Configuration parameters (6/8)
No reproduction or communication without the written consent of SAGEM SA
Installation and User Guide - N56717020104
2 - OPERATION
Default
value
CT
E1
CT
"Management
Use"
CO
"G.703"
"SDH
Subnetwork
Clock"
"Default Edge"
"E3 (34M)"
"short"