1 - INSTALLATION AND COMMISSIONING
1.3.3.3 – Connecting with MSP operation
As EOW and AUX ports are physically integral with ADR Optical, operating the order wire and
auxiliary channels with MSP protection requires the use of a "Y" cord electrically connecting, one
by one, identically, the signals of EOW and AUX connectors.
"Y" cord for
order wire
channel operation
Likewise, in order to ensure a good behaviour during the changeover from one module to the
other, the operator should take care to keep identical configurations on both ADR Optical cards ;
in case of modification, automatic recopy is done and a warning message appears.
Only the connections are not identical. There must be no connections on the "Protection"
module, as in all the connections are made to the "Working" module.
Cables' Codification
See paragraph 3 "Spare parts and Cables"
Installation and User Guide - N56717020104
Page A1-16
No reproduction or communication without the written consent of SAGEM SA
EOW
TR
ADR Optical Working
TR
EOW
ADR Optical Protection
REC
AUX
REC
AUX
"Y" cord for
auxiliary wire
channel operation