Use

Preconditions for use

The mask/helmet combination needs to be carefully adapted to the
equipment wearer (correct mask size, mask guide settings and
internal helmet components) due to the rigid structure.
Strictly follow the national regulations for the use of respiratory
protective devices (in Germany for example BGR 190, in Australia
and New Zealand for example AS/NZS 1715:2009).

Selecting the correct mask size

The mask bodies are available in sizes S, M, L, inner masks in sizes
1, 2, 3 and head harnesses in sizes M/L and S. In most cases, the
standard size M2 is used. If this size cannot ensure sufficient leak
tightness, another size combination must be used.
WARNING
Each mask wearer must be provided with a mask of suitable size.
Prior to use, always make sure that the Dräger FPS 7000 RP is leak-
tight. The sealing surface between head and mask body must be
free of hair and foreign objects as these could cause leakages.
Spectacle wearers should wear mask spectacles.
 Select the correct mask size.
 Before using the Dräger FPS 7000 RP for the first time, check that
it is leak-tight (see "Leak tests" on Page 27).
22
Preparing the Dräger FPS 7000 RP for use
 Install mask spectacles, if necessary
 If necessary, install the telephone device or Dräger MS-COM
.
If the holder for the Dräger MS-COM is mounted, the Dräger
FPS 7000 RP may only be used with the communication system
fitted or with a protective cap. Otherwise there is risk of injury.
Mask/
 Adjust the mask guide and the internal helmet
helmet
components.
combina-
tion
 Remove protective foil from visor.
 Soak the wiper with "klar-pilot" comfort anti-fog agent.
Apply the anti-fog agent to the inside of the visor and wipe with a
lint-free cloth until visibility through the visor is good.
Do not operate the wiper in dry condition.
 If the Dräger FPS 7000 RP is equipped with a drinking valve,
make sure that the protective cap is on the drinking valve.
Alternatively, the drinking tube can be fitted onto the drinking
valve.
If the drinking valve will not be used during the entire mission, the
mouthpiece should be removed. This will increase the wearing
comfort of the mask.
Full face
 Loosen the harness as far as possible.
mask
 Put neck strap around the neck and fasten the Dräger
FPS 7000 RP in standby position (Figure B).
1)
Strictly follow the corresponding assembly instructions.
(approved by Dekra Exam)
1)
.
CAUTION
NOTICE
1)