Manufacturer
Lubricant
Mobil DTE Oil BB
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Check the oil level and if necessary refill from the oil dipstick
pos. , Fig. 3.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing: the
oil dipstick, pos. , and then the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
the table in chapter 11.
The quantity required is ~ 3.8 liters.
Viscosity / Room Temperature diagram
mm
/s = cSt
2
The used oil must be poured unto a suitable container and consigned to an authorized recycling center.
It absolutely must not be discarded into the environment.
Set up the plant so that the oil temperature never
exceeds 110°C (230°F) during pump operation
under any circumstances.
Use a temperature probe to be inserted into the
oil drain plug pos.(2) fig.3. See "ATEX EXPLOSION
PROTECTION" manual.
ATTENTION: Use only oil with a flash point higher
than 200°C.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0°C - 30°C, follow
the instructions in the following diagram, considering that oil
must have a minimum viscosity of 180 cSt.
Ambient temp. (°C)
24
Fig. 3