Troubleshooting

The following table will assist you in fixing faults:
Problem
Device does not start
Device works with inter-
ruptions
Strong vibrations, loud
noises
Bad cutting results
32
Possible cause
Rechargeable battery (17)
discharged
Rechargeable battery (17)
not inserted
On/Off switch (2) is
broken
Defective motor
Internal loose contact
On/Off switch (2) is
broken
Cutting unit dirty
Defective motor
The line spool (11) does
not have enough cutting
line
The cutting line is not
guided out of the spool
cap (12)
Cutting unit dirty
Low battery power
Troubleshooting
Charge the battery (see
the separate operating
instructions for the re-
chargeable battery and
charger)
Inserting the battery,
p. 29
Contact the service
centre.
Contact the service
centre.
Clean the cutting unit (see
Cleaning, maintenance
and storage, p. 30)
Contact the service
centre.
Extending the cutting line,
p. 27
Replacing the spool
(Fig. D), p. 30
Remove the spool cover
(23) from the spool cap
and thread the cutting
line through the line outlet
loop (10) to the outside,
then close the spool cov-
er again
Clean the cutting unit (see
Cleaning, maintenance
and storage, p. 30)
Charge the battery (see
the separate operating
instructions for the re-
chargeable battery and
charger)