Table des Matières

Publicité

E N
    AC T I VAT I O N
7 P R E S S U R E R E G U L AT I N G ( S B H - G )
The pressure is variable setable from approximately 60 bar with a turnover from
2 l/min. to the maximum capacity as it been indicated on the machine.
8 WO R K I N G S H O U R S C O U N T E R
The workings hours counter is situated at the front at the control panel. The
counter shows the number of hours that he machine has worked.
9 R E S E T B U T TO N ( S B H - G )
The reset button is an illuminated push button. If the reset button is being
pushed during 3 seconds (or more) , you receive an error message where the
fault can be determined by means of a flash frequence.
10 G A S VA LV E I N D I C AT I O N L E D ( S B H - G )
The indication led lights up when the gas valve is opened and the burner is
active.
11 S P R AY I N G TO O L S
The HP- spray gun have been carried out with a grey handle
• Not spraying: release the lever in the handle.
• Spraying: pressing the lever in the handle.
• Spray security: slap the block-system out in the lever.
Checks during praying regularly or the lance coupling still sits firmly on the gun.
The machine is standard provides with a single lance.

SET TO WORK

1

SBH-D

• Put the high pressure cleaner as much as possible in a horizontal position.
• Connect the spray gun with the high pressure hose (without spray lance) to
the high pressure cleaner.
• Connect the high pressure cleaner electrical (plug in socket, 230/400V).
• Turn the main switch to position 1=ON.
• Aim the spray gun in to the free space and operate the spray gun until the
water jet is completely de aerated (+- 30 sec.).
• Turn the main switch to position 0=OFF.
• Connect the spray lance to the spray gun.
• Turn the main switch to position 1=ON.
• Operate the spray gun and check the working pressure on the pressure
gauge. Adjust if necessary the pressure regulator for the right spray pressure.
• For the use of hot water one must turn the main switch to position 2=BURNER.
• Adjust at use of hot water the temperature regulating button tot the desired
position.
• Adjust the concentration from the added chemicals by opening the mixing
valve on the spray lance to your needs.
DiBO 18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1.780.482

Table des Matières