IMPORTANT: The "CONTINUOUS" CYCLe STARTS WheN The K5GRx KeY IS ReLeASeD (WIThIN 5
SeCONDS OTheRWISe The PROGRAMMING PhASe beGINS) AND NOT WheN IT IS PReSSeD. IN-
STeAD, DOSAGe STOPS WheN The KeY IS PReSSeD.
TeA CYCLe
DISPeNSING
When the key relating to the Tea dose is pressed (K6GRx), the Tea solenoid valve is activated (EVtEa) and
hot water is dispensed. This operation is indicated by the LeD (l6GRx) corresponding to the key pressed
lighting up.
When the cycle starts, a Timer is activated which, once the time value set during the programming phase is
achieved, interrupts product dispensing.
the dosage function permits the contemporary dispensing of tea and coffee cycles.
The display shows
Stop dispensing tea while in progress
It is possible to interrupt dispensing while in progress before the programmed amount of time has passed.
Simply press the same key used to start dispensing the tea dose.
This de-energises with immediate effect the solenoid valve EVtEa and interrupts product dispensing and
returning the dosage to idle-on status.
The control unit is designed to manage three different tea doses (one per unit).
TeA + PUMP
Tea dispensing can be combined with the pump.
See TeChNICAL LeVeL Programming.
AUTOSTeAM SPOUT DISPeNSING CYCLe
This function and the keyboard dedicated to perform it is activated in TeChNICAL LeVeL Programming (see
relevant paragraph)
Thanks to a temperature probe suitably positioned on the steam spout and connected to the STLVAP input,
the temperature of the liquid heated by the steam is measured.
So by pressing the AUTOSTeAM key in position K6GRx key the eVVAP is activated until the temperature set
in the Programming for Simulation is reached (see paragraph below).