Technical Data; Before Starting The Equipment; Attachment And Operation; Mains Connection - Scheppach HC120DC Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
• A pressure vessel is not allowed to be used if it has
faults or deficiencies that can endanger workers or
third parties.
• Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure ves-
sel. If you discover any damage, then please con-
tact the customer service workshop.
Do not lose these safety instructions

6. Technical data

Mains connection

Motor rating
Operating mode
Compressor speed
Pressure vessel capacity
(in liters)
Operating pressure
Theoretical intake capacity
(l/min)
Sound power level L
WA
Uncertainty K
WA
Protection type
Weight of the unit in kg
Oil (15W 40) l
Max. altitude
(above mean sea level)
The noise emission values were measured in ac-
cordance with EN ISO 3744.
Wear hearing protection.
The effects of noise can cause a loss of hearing.

7. Before starting the equipment

• Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
• Prior to initial commissioning, remove the transport
plug (B) and fill the crank housing with oil as de-
scribed in item 8.4.
• Check the equipment for damage which may have
occurred in transit. Report any damage immedi-
ately to the transport company which was used to
deliver the compressor.
• Install the compressor near the point of consump-
tion.
• Avoid long air lines and supply lines (extension ca-
bles).
• Make sure that the intake air is dry and dustfree.
20 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
230 V / 50 Hz
2200 W
S1
2850 min
-1
100
approx. 10 bar
approx. 412
97 dB(A)
2,03 dB
IP20
approx. 58
approx. 0,25
1000 m
• Do not install the compressor in a damp or wet
room.
• The compressor may only be used in suitable
rooms (with good ventilation and an ambient tem-
perature from +5 °C to 40 °C). There must be no
dust, acids, vapors, explosive gases or inflamma-
ble gases in the room.
• The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in ar-
eas where work is conducted with sprayed water.
• The oil level in the compressor pump has to be
checked before putting the equipment into opera-
tion.

8. Attachment and operation

m Important!
You must fully assemble the appliance before using it
for the first time!
You will require the following tools for assembly and
installation:
• 2 x open-ended wrench size 19 mm (not included)
• 2 x open-ended wrench size 14 mm (not included)
8.1 Fitting the wheels (Fig. 5)
• Fit the supplied wheels (11) as shown.
8.2 Fitting the supporting foot (2x) (Fig. 6)
• Fit the supplied supporting foot (2x) as shown.
8.3 Fitting the air filter (2x) (Fig. 7, 8)
• Remove the transportation stop (A) and screw the
air filter (14) to the equipment.
8.4 Changing the transportation cover (B)
(Fig. 9, 10)
• Remove the transport lid (B) of the oil filling open-
ing (19).
• Fill the included compressor oil into the crank
housing and insert the included oil sealing plug
(15) into the oil filling opening (19).
8.5 Mains connection
• The compressor is equipped with a mains cable
with shock-proof plug. This can be connected to
any 230-240 V ~ 50 Hz shock-proof socket.
• Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
• Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
• At low temperatures below +5°C, sluggishness
may make starting difficult or impossible.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5906120905

Table des Matières