Technical Data; Before Starting The Equipment; Attachment And Operation; Mains Connection - Scheppach HC53dc Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
• A pressure vessel is not allowed to be used if it
has faults or deficiencies that can endanger work-
ers or third parties.
• Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure ves-
sel. If you discover any damage, then please con-
tact the customer service workshop.
Do not lose these safety instructions

6. Technical data

Mains connection

Motor rating W
Operating mode
Compressor speed
Pressure vessel capacity
(in liters)
Operating pressure
Theoretical intake capacity (l/
min)
Sound power level L
WA
Uncertainty K
WA
Protection type
Weight of the unit in kg
Oil (15W 40) l
Max. altitude
(above mean sea level)
The noise emission values were measured in accord-
ance with EN ISO 3744.
Wear hearing protection.
The effects of noise can cause a loss of hearing.

7. Before starting the equipment

• Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
• Prior to initial commissioning, remove the trans-
port plug (B) and fill the crank housing with oil as
described in item 8.4.
• Check the equipment for damage which may have
occurred in transit. Report any damage immedi-
ately to the transport company which was used to
deliver the compressor.
• Install the compressor near the point of consump-
tion.
• Avoid long air lines and supply lines (extension
cables).
• Make sure that the intake air is dry and dustfree.
• Do not install the compressor in a damp or wet
room.
40 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
230 V~ 50 Hz
2200
S1
2850 min
-1
50
approx. 10 bar
approx. 412
93 dB(A)
2,03 dB
IP20
approx. 44,5
approx. 0,25
1000 m
• The compressor may only be used in suitable
rooms (with good ventilation and an ambient tem-
perature from +5 °C to 40 °C). There must be no
dust, acids, vapors, explosive gases or inflamma-
ble gases in the room.
• The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed water.
• The oil level in the compressor pump has to be
checked before putting the equipment into opera-
tion.

8. Attachment and operation

m Important!
You must fully assemble the appliance before using it
for the first time!
You will require the following tools for assembly and
installation:
• 2 x open-ended wrench size 17 mm (not included)
• 2 x open-ended wrench size 14 mm (not included)
8.1 Fitting the wheels (Fig. 5)
• Fit the supplied wheels (11) as shown.
8.2 Fitting the supporting foot (2x) (Fig. 6)
• Fit the supplied supporting foot (2x) as shown.
8.3 Fitting the air filter (2x) (Fig. 7, 8)
• Remove the transportation stop (A) and screw the
air filter (14) to the equipment.
8.4 Changing the transportation cover (B)
(Fig. 9, 10)
• Remove the transport lid (B) of the oil filling open-
ing (19).
• Fill the included compressor oil into the crank
housing and insert the included oil sealing plug
(15) into the oil filling opening (19).
8.5 Mains connection
• The compressor is equipped with a mains cable
with shock-proof plug. This can be connected to
any 230 - 240 V~ 50 Hz shock-proof socket.
• Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
• Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
• At low temperatures below +5°C, sluggishness
may make starting difficult or impossible.
8.6 ON/OFF switch (Fig. 2)
• Pull the ON/OFF switch (16) upwards to switch
on the compressor. To switch off the compressor,
press the ON/OFF switch down.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5906102901