Alarm Codes - Siemens SITRANS FUS1010 Guide Rapide

Masquer les pouces Voir aussi pour SITRANS FUS1010:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Quick Start Guide
Final Flowmeter Setup
Siemens
2 Channel
Key [Install] after mounting transducers
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Complete
Empty Pipe Set
Zero Flow Adjust
Install Xdcr

Alarm Codes

Alarm Letter Codes and Descriptions
SPACE ............... Spacing ..................... Transducer spacing may need re-adjustment
EMPTY .............. Empty ........................ Pipe is empty
HI/LO ................ Rate ........................... Flow above High setting or below Low setting
FAULT ................ Fault .......................... Three continuous seconds without new data update
AER .................. Aeration .................... Current aeration percentage exceeds the alarm setpoint
MEMRY ............. Memory ..................... Last valid reading for a selected interval during Fault condition
MAKUP ............. Makeup ..................... In-Process Makeup occurred
The following alarm codes appear in the Datalogger status messages:
I ....................... Interface .................... Liquid Vs exceeds interface alarm setpoint
P ....................... Pig ............................. Pig passage detected (optional)
Z ...................... ZeroMatic .................. ZeroMatic signal fault
The displays shown below indicate where the Alarm Codes appear on the screen. Press <Up> or <Down> Arrows to change
screen views.
Siemens
2 Channel
FLOW GAL/MIN
14.35
FAULT
SPACE
MAKUP
TOTAL
GAL
354.6597
Alarm Codes
16
Transducer Installation / Alarm Codes
At the Flow Display Computer, scroll down to [Install Complete]. Press <Right Arrow> and
select [Install]. Press <ENT>. Flow Display Computer will go through drives.
Observe the Measured Vs window and verify a correct sound velocity measurement (if
known).
Press the <Down Arrow> to accept sound velocity value.
The meter is now ready to report flow. Press the <MENU> key twice to display flow.
[1]
ABC
1011HP-T1
D1H
Reflect
Nominal
26
Spacer Bar 1012BN
7.499
Yes
Channel Not Setup
Channel Not Setup
Refer to I/O Connection diagrams for input/output wiring and Flow Display Computer
manual for data spanning procedures.
[1]
Unit#1
100.0
Vf
Vs
1427
0.0
31.74
Siemens
Drive 14
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Complete
Empty Pipe Set
Zero Flow Adjust
Install Xdcr
Siemens
FAULT
AER
HI/LO
Alarm Codes
30.0
Vs
G/M
-30.0
11.40
2 Channel
[1]
ABC
[06:--------------------:0]
1011HP-T1
D1H
Reflect
Measured Vs m/s
Minimum
1469
4
Spacer Bar 1012BN
7.499
Install
Channel Not Setup
Channel Not Setup
2 Channel [1]
Vs
FLOW: GAL/MIN
1286
68.10
NTOTAL: GAL
112.38
Unit #1
ALC
AER
63
2
9/26
12:45