Siemens SITRANS FUS1010 Guide Rapide page 6

Masquer les pouces Voir aussi pour SITRANS FUS1010:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Quick Start Guide
————————————————————————————————————————
Ratings on this Page Apply to Model Families: FUS1010 7ME3531, FUH1010 7ME3601,
FUG1010 7ME3611 only; Check Your Model Number
————————————————————————————————————————
FM-CSA INSTALLATION:
media provided. This equipment is rated for use in hazardous (classified) locations as stated below
and must be installed according to the 1010-341 installation drawing provided on the media. Failure
to install the equipment in the prescribed manner will result in unsafe operation. Follow all local
jurisdictional safety codes when operating this equipment. When properly installed the equipment
meets the following FM – CSA ratings:
Flow Meter:
- Explosionproof for Class I, Division1, Groups B, C, D;
- Dust-ignitionproof for Class II, Division 1, Groups E, F and G
- Intrinsically safe connections for Class I and II, Division 1, Groups A, B, C, D, E, F and G;
- Non-incendive for Class I, Division 2, Groups A, B, C and D;
- Suitable for Class II Division 2 Groups E, F and G outdoor (Type 4X)
Transducers:
- Intrinsically safe connections Class I and II, Division 1, Groups A, B, C, D, E, F and G;
- Nonincendive for Class I, Division 2, Groups A, B, C and D;
- Suitable for Class II Division 2 Groups F and G outdoor (Type 4X)
- Temperature code T5 at an ambient of 40°C
ATEX INSTALLATION:
media provided. This equipment is rated for use in explosive atmospheres as stated below and must
be installed according to the 1010-422 installation drawing provided on the media. Failure to install
the equipment in the prescribed manner will result in unsafe operation. Follow all regional safety
laws when operating this equipment. When properly installed the equipment meets the following
ATEX ratings as stated in EC-Type Examination Certificate KEMA03ATEX2133
Flow Meter:
II 2 (1) G EEx d [ia] IIC T5 – Category 2 Flow meter located in Zone 1 hazardous area with intrinsically
safe circuits of category Ex ia, which can be connected to Category 1 transducers for use in potentially
explosive atmosphere containing gases
IP65 – Ingress protection against solid bodies, rating of dust-tight and against liquid, rating of water jets
Transducers:
II 1 G EEx ia IIC T5 – Category 1 Transducers located in Zone 1 hazardous area with intrinsically safe
circuits of category Ex ia for use in potentially explosive atmosphere containing gases
IP65 – Ingress protection against solid bodies, rating of dust-tight and against liquid, rating of water jets