Siemens SITRANS FUS1010 Guide Rapide page 4

Masquer les pouces Voir aussi pour SITRANS FUS1010:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Quick Start Guide
————————————————————————————————————————
Ratings on this Page Apply to Model Families: FUE1010 7ME3500, FUG1010 7ME3610,
FUH1010 7ME3600 and FUS1010 7ME3530 only; Check Your Model Number
————————————————————————————————————————
FM-CSA INSTALLATION:
media provided. This equipment is rated for use in hazardous (classified) locations as stated below
and must be installed according to the 1010-304 installation drawing provided on the media. Failure
to install the equipment in the prescribed manner will result in unsafe operation. Follow all local
jurisdictional safety codes when operating this equipment. When properly installed the equipment
meets the following FM – CSA ratings:
Flow Meter:
- Intrinsically safe connections Class I and II, Division 1, Groups A, B, C, D, E, F and G;
- Nonincendive for Class I, Division 2, Groups A, B, C and D;
- Suitable for Class II Division 2 Groups F and G outdoor (Type 4X)
- Temperature code T5 at an ambient of 40°C
Transducers:
- Intrinsically safe connections Class I and II, Division 1, Groups A, B, C, D, E, F and G;
- Nonincendive for Class I, Division 2, Groups A, B, C and D;
- Suitable for Class II Division 2 Groups F and G outdoor (Type 4X)
- Temperature code T5 at an ambient of 40°C
ATEX INSTALLATION:
media provided. This equipment complies with Directive 94/9/EC and is rated for use in potentially
explosive atmospheres. The equipment markings are shown and explained below. Equipment must
be installed according to the 1010-389 installation drawing provided on the media. Failure to install
the equipment in the prescribed manner will result in unsafe operation. Follow all regional safety
laws when operating this equipment. When properly installed the equipment meets the following
ATEX ratings as stated in EC-Type Examination Certificate KEMA03ATEX1134
Flow Meter Markings and Explanations:
II (1) G [EEx ia] IIC – Flow meter located in the non-hazardous area with intrinsically safe circuits of
category Ex ia, which can be connected to Category 1 transducers
II 3 (1) G EEx nC [ia] IIC T5 – Category 3 Flow meter located in Zone 2 hazardous area with intrinsically
safe circuits of category Ex ia, which can be connected to Category 1 transducers in Zone 0
IP65 – Ingress protection against solid bodies, rating of dust-tight and against liquid, rating of water jets
Transducers Markings and Explanations:
II 1 G EEx ia IIC T5 – Category 1 Transducers located in Zone 1 hazardous area with intrinsically safe
circuits of category Ex ia for use in potentially explosive atmosphere containing gases
IP65 – Ingress protection against solid bodies, rating of dust-tight and against liquid, rating of water jets
4
Quick Start Guide Safety Information
for Hazardous Areas
Read, understand and follow all safety instructions on the electronic
Read, understand and follow all safety instruction on the electronic

Publicité

Table des Matières
loading

Table des Matières