Quick Start Guide
Note: Before creating a site select a Language and then English or Metric units from the Meter Facilities Menu.*
1. Select a Meter Type
Select for summing or
subtracting flow from
two different pipes.
2. Create a Site
*Note: To set English or
Metric units:
In Meter Type Menu, scroll
to Meter Facilities Menu.
Press <Right Arrow> and
select preferred units. Press
<ENT> to select. Press <Left
Arrow> and <Up Arrow> to
return to main menu.
3. Pipe Data

Flowmeter Programming

Press the <MENU> key and select the Meter Type.
Press the <Right Arrow> and scroll to [2 Channel Flow]. Press <ENT> to select.
Note: Select [2 Channel Flow] if measuring two different pipes and [Dual Path Flow] if
sensors are mounted on the same pipe.)
Press <Right Arrow to select [Channel 1] [Clamp-on]. Press <ENT> to select.
Siemens
2 Channel [1]
Select Meter Type
Meter Type
>2 Channel Flow
Meter Facilities
Dual Path Flow
Language
Ch 1 + 2 Flow
Ch 1 - 2 Flow
Before proceeding make sure that English or Metric units have been selected.*
At the [Channel Setup] menu press <Right Arrow> and enter a Site name.
Press <ENT> to create Site name (e.g., ABC). (See figure below.)
Siemens
2 Channel [1]
Right Arrow & Enter Creates a new Site
Recall Site
Channel Enable
Create/Name Site
Site Security
Delete Site Setup
Save/Rename Site
Channel Setup
Scroll to [Save/Rename Site]. Press <Right Arrow> then press <ENT> to save site.
Press the <Left Arrow> and return to the main menu.
Pick Pipe Class
Press the <Right Arrow> to select Pipe Class. Press <Right Arrow> again and scroll to
desired Pipe Class.
Press <ENT> to select.
Pre-programmed Pipe Size and relevant pipe parameters will appear in menu cells.
Press <Right Arrow> and scroll to desired pipe size. Press <ENT>. Enter dimensions
manually if pre-programmed dimensions do not match your application.
Siemens
2 Channel
Pick Pipe Class
Pick Pipe Class
Select Pipe Size
Pipe OD <in>
Pipe Material
Wall Thickness
Liner Material
Liner Thickness
Pipe Data
Press the <Left Arrow> and return to the main menu.
Channel 1
Channel 1
No Sites
No
?
Off
No Sites
[1]
ABC
ASA Carb. Steel
8CS40
8.625
Steel
0.322
None
0.000
Select for measuring two
different pipes. (Not avail-
able for all models.)
Select if two sensors are
mounted on the same
pipe.
Insert desired name
(8 characters max.).
Note: To select letters:
Press <Right Arrow> to
cursor and then press
<Up/Down Arrows> to
select letters. Press
<ENT> when done.