5.

OPERATIONS FOR COMMISSIONING

GENERAL WARNINGS
Operators have a duty to familiarise themselves adequately, using this manual before performing
any intervention, adopting the specific safety requirements to make every kind of human-com-
puter interaction safe.
Any technical modification that affects the operation or safety of the machine must only be car-
ried out by the technical personnel of the manufacturer or by technicians that are formally au-
thorised by the manufacturer. Failure to do so exempts the manufacturer from any liability for for
any possible resulting modifications or damage.
Even after appropriate familiarisation, upon the first use of the appliance, in any case simulate a
number of test operations to save more rapidly the main functions of the appliance, e.g. start-up,
shut-down, etc.
The appliance is provided already tested by the manufacturer and fitted with the type of gas and
electrical supply specified on the rating plate applies.
5.1 FIRST COMMISSIONING START UP
Upon completion of the operations of positioning and connection to the power sources including those relating
to the drainage network, perform a series of operations such as:
1. Cleaning away of the protective materials (oils, grease, silicones, etc.) inside and outside of the cooking
chamber (see section 3.5)
2. Analysis of the combustible gases (only for models with gas supply).
3. General checks and controls such as: Check opening of switches & network gate valves (water, electricity,
gas when applicable); Checking of drains; Checking and monitoring of the external fumes/vapour extraction;
Checking and monitoring of the protection panels (all the panels must be fitted correctly).
5.2 CONTROL AND REGULATIONOF THE GROUPS GAS SUPPLY
With the connection operations described in the previous sections completed, the appliance,
even if correctly calibrated during the testing phase, requires partial verification of the param-
eters set directly at the place of final destination.
The first parameter to be checked allows verification via the type of power supplied by the body
dispensing the correct pressure present.