Light Reserve; Shift Sensor - Raleigh PEDELEC IMPULSE EVO Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Navigate to "Wheel circumference" as described in
settings in the main menu Page
You can pick values between:
»
1,510 mm to 2,330 mm
2. Use the / buttons to select the option required. The option selected
is highlighted.
3. Confirming the wheel circumference with returns you to sub-level 2.
6.4.3.14

Light reserve

Path: Settings | Device settings | Drive | Light reserve
When enabled, the Light reserve function keeps back part of the battery
power for long-term light function. Light reserve is retained for two hours
once assist power is no longer being provided. This function is set as
standard and can be disabled.
1. Navigate to "Light reserve" as described in
settings in the main menu Page
2. Use the / buttons to select "Yes" or
"No". The option selected is highlighted.
3. Confirming with returns you to sub-level
2.
 6.4.1 Configuring
EN-54.
 6.4.1 Configuring
EN-54.
11:18
OFF
0.0
Trip 0.0 km
Light reserve is enabled
WARNING
We recommend keeping the light reserve switched on. Otherwise the
lights and the Impulse Evo / Impulse Evo Next system go out at the
same time. If you are out and about in poor light (in fog, rain, early
morning, late evening), you run the risk of not being seen, and as a
result of a serious accident.
6.4.3.15

Shift sensor

Path: Settings | Device settings | Drive | Shift sensor
The shift sensor detects gear changes and interrupts the motor assist for
a fraction of a second (ms = milliseconds). This enables smoother and
quicker gear changes especially with a hub gear. This makes the shift
process more gentle for the pedelec. The higher the value selected, the
longer the interruption to the motor assist and the more time the gear has
to change.
1. Navigate to "Shift sensor" as described in
in the main menu Page
You can choose between:
140km
OFF
50 ms
km/h
Short interruption
2. Use the / buttons to select the desired option. The option selected
is highlighted.
3. Confirming with returns you to sub-level 2.
Original User Guide | Pedelec Impulse Evo / Impulse Evo Next Version 4
 6.4.1 Configuring settings
EN-54.
100 ms
150 ms
200 ms
Long interruption
250 ms
300 ms
EN-65