Installation instructions, only for experts
Activating single-sensor mode
In single-sensor mode, the sauna control unit is operated with the heater sensor
with an excess temperature fuse (F1) only. The two-sensor mode is activated as
standard. If you wish to activate the single-sensor mode, perform the following
steps:
1. Open the technician menu (see 26).
2. Turn the bottom knob to the temperature symbol (position A – see point 9.2
on page 31).
► The temperature symbol fl ashes.
► In the top display, "SEnB" appears.
► In the bottom display, "On" appears.
("On" means that the two-sensor mode is activated.)
3. Turn the bottom knob to the left.
► In the bottom display, "OFF" appears.
► The single-sensor mode is activated.
Displaying the heater temperature in single-sensor mode
In single-sensor mode, the sauna control unit only displays the set temperature
as standard. The actual temperature is not displayed. Should the sauna control
unit display the temperature above the heater (F1) as an actual temperature in
single-sensor mode, it must be activated in the technician menu.
1. Open the technician menu (see page 26).
2. Activate the single-sensor mode (see page 27).
► The top display shows "SEnB".
► The bottom display shows "OFF".
3. Press the bottom knob.
► In the top display, "dISP" appears.
► In the bottom display, "SEt" appears.
("SEt" means that only the set temperature is displayed in single-sensor mode.)
4. Turn the bottom knob to the left.
► In the bottom display, "SEnS" appears.
► The heater temperature (F1) is displayed as the actual temperature in
the single-sensor mode.