Technical Data - Sentiotec Pro C2 Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Instructions for installation and use

16. Technical data

Ambient conditions
Storage temperature:
Ambient temperature:
Relative humidity:
Sauna control unit
Dimensions:
Switched voltage/three-phase 3N:
Frequency:
Contact rating/heater:
Switched current per phase/heater:
Contact rating/additional output (dimmable)
Contact rating/additional output (switchable)
Switched current/additional output:
Status output:
Rated voltage:
Protection type (protected against jets of water):
Connection to the mains supply as fi xed wiring (fi xed connection)
Light
Contact rating:
Fuse:
Fan
Contact rating:
Fuse:
Setting ranges
Temperature:
WORLD OF WELLNESS
p. 47/48
-25 °C to +70 °C
-10 °C to +40 °C
max. 95%
307 x 175 x 57 mm
400 V AC
50 Hz
3 x 3.5 kW
16 A
500 W
3.5 W
16 A
24 V/200 mA
230 V
IPX4
100 W
1A T
100 W
1A T
30 °C to 110 °C
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pro c3Pro-c2

Table des Matières