Installation instructions, only for experts
6.

Performing tests

The following tests must be performed by a certifi ed electrical fi tter.
WARNING!
The following tests must be performed with the power supply
switched on. There is a danger of electric shock.
● NEVER touch live parts.
1. Check the contact of the earth conductors on the earth conductor terminal.
2. Check the excess temperature fuse on the heater sensor F1.
a. Switch on the sauna control unit.
b. Open the heater sensor and disconnect one of the two red wires for
the heater sensor.
► A recurring warning tone is emitted, "Err" shows in the top display,
"02" shows in the bottom display.
► The control unit switches off the heater.
c. Switch off the sauna control unit.
d. Reconnect the red wire for the heater sensor.
e. Now disconnect one of the white wires for the heater sensor.
f.
Switch on the sauna control unit.
► A recurring warning tone is emitted, "Err" shows in the top display,
"04F1" shows in the bottom display.
► The control unit switches off the heater.
g. Switch off the sauna control unit.
h. Reconnect the white wire for the heater sensor.
3. Check the phase circuit for sauna mode L1, L2, L3 is connected to U, V, W.
4. Ensure the phase circuit for L3 is connected to W1 when the device con-
nected to the additional output is activated.
WORLD OF WELLNESS
p. 21/48