15

What if there are problems?

If the scale detects and error when measuring, the following is displayed.
Display
Cause
0_Ld
The maximum load capacity of 150 kg
was exceeded.
Lo
The batteries are almost empty.
Err
The electrical resistance between the
electrodes and the sole of your foot is
too high (e.g. if you have tough cal-
luses).
The fat percentage is outside the
measurable range (less than 5% or
greater than 50%).
The water percentage is outside the
measurable range (less than 36% or
greater than 70%).
The muscle and bone percentages
are outside the measurable range
(age and gender related).
Full Data
30 measurements have been saved.
No display
The batteries in the control unit are
completely empty.
The batteries in the control unit are
not inserted correctly.
No measurement possible
Possible errors
The scale was not activated before
you stood on it. If you step on the
scale before "0.0 KG" is displayed,
the scale will not work correctly.
Cordless connection between scale
and control unit is interrupted.
The control unit is too far away from
the scale.
The batteries in the scale are emp-
ty.
32
Remedy
Do not load the unit with over 150 kg.
Replace the batteries (see page 22 and
31).
Repeat the measurement barefoot. If nec-
essary, moisten the soles of your feet
slightly. If necessary, remove the calluses
from the soles of your feet.
Repeat the measurement barefoot or, if
necessary, moisten the soles of your feet
slightly.
Repeat the measurement barefoot or, if
necessary, moisten the soles of your feet
slightly.
Repeat the measurement barefoot or, if
necessary, moisten the soles of your feet
slightly.
Transfer the measurements to your PC.
Replace the batteries (see page 22).
Check to ensure that the polarity is correct
(see page 22)
Remedy
Activate the scale correctly (wait for "0.0 KG") and repeat
the measurement.
Switch on the control unit first before the measurement. If
necessary, wait 30 seconds, then repeat the measurement.
Briefly remove, then reinsert the batteries of the scale and
the control unit; the scale sends an audible signal when you
insert the batteries.
Maintain a larger distance from the following electromag-
netic sources: high-voltage pylons, television or wireless
computer systems, fitness equipment, mobile phones,
weather stations.
Reduce the distance between the scale and control unit;
maximum distance is 2 metres.
Replace the batteries (see page 22).

Publicité