Scope Of Delivery; Accessories - Wilo SiBoost Smart Série Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 113
Connection
Suction/pressure pipe
Permitted ambient temperature
Permissible fluids
Permissible fluid temperature
Max. permitted operating pressure
Max. permissible inlet pressure
Further data...
Diaphragm pressure vessel

5.3 Scope of delivery

• Pressure-boosting system
• Installation and operating instructions for the
pressure-boosting system
• Installation and operating instructions for the
pumps
• Installation and operating instructions for the
control device
• Factory acceptance inspection certificate
(in accordance with EN 10204 3.1.B)
• Installation plan if applicable
• Electrical circuit diagram if applicable
• Installation and operating instructions for the
frequency converter if applicable
• Supplementary sheet with the factory setting
of the frequency converter if applicable
• Installation and operating instructions for the
signal transmitter if applicable
• Spare parts list if applicable
Installation and operating instructions Wilo-SiBoost Smart (FC) ... Helix V/... Helix VE/... Helix EXCEL
DN 100/ DN 100
(..2 Helix V/VE/EXCEL 36..)
(..3 Helix VE/EXCEL 16..)
(..3 Helix V/VE/EXCEL 22..)
(..4 Helix V/VE/EXCEL 16..)
(..3 Helix V 16..(60 Hz))
(..4 Helix V 16..(60 Hz))
DN 125/ DN 125
(..2 Helix V/VE/EXCEL 52..)
(..3 Helix V/VE/EXCEL 36..)
(..4 Helix V/VE/EXCEL 22..)
DN 150/ DN 150
(..3 Helix V/VE/EXCEL 52..)
(..4 Helix V/VE/EXCEL 36..)
DN 200/ DN 200
(..4 Helix V/VE/EXCEL 52..)
(Subject to change without prior notice / see also supplied installation
plan)
5 °C to 40 °C
Pure water without settling sediments
3 °C to 50 °C (deviating values on request)
On the pressure side 16 bar (see rating plate)
Indirect connection (but max. 6 bar)
8 L

5.4 Accessories

Accessories must be ordered separately as
required. The accessories from the Wilo range
include the following:
• Open break tank (example in Fig. 13a)
• Larger diaphragm pressure vessel (on the suction
or discharge side)
• Safety valve
• Dry-running protection system:
• For systems with frequency control on every
pump (SCe): For operation with supply pressure,
a supply pressure sensor is fitted on the suction
side as standard that functions as a low-water
cut-out switchgear (Fig. 6d or 6e).
• On systems without frequency control but
with supply pressure (inlet mode, supply pres-
sure of at least 1 bar), a separate assembly is
ready fitted as a dry-running protection (WMS)
(Fig. 6a and 6c) if it is contained in the order
scope.
• Float switch
• Low-water warning electrodes with level con-
trol relay
• Electrodes for tank operation (special accesso-
ries on request)
• Flexible connection pipes (Fig. 10 - B)
• Compensators (Fig. 9 - B)
• Threaded flanges and caps (Fig. 9 and 10 - D)
• Sound-insulating unit casing (special accessories
on request)
English
11

Publicité

Table des Matières
loading

Table des Matières