36 | TCE 4335 | Maintenance
6.
Maintenance
6.1
Suggested lube
Component
Lube
Gearbox
ESSO Spartan EP460 ISO 460
Pneumatic system
ESSO FEBIS K 32
(conditioning assem-
bly)
Tab. 1:
Lubricants table.
!
The manufacturer is not liable for any damage
caused by use of lubes different from those shown in
the table.
6.2

Cleaning and servicing

Before any cleaning or maintenance interven-
tion, disconnect the TCE 4335 by means of
the main switch and disconnect the network
plug.
Before any cleaning or maintenance interven-
tion, disconnect the pneumatic system of the
TCE 4335.
To guarantee full efficiency of the TCE 4335 and to
ensure functioning without anomalies it is essential to
clean the machine regularly and carry out periodical
maintenance.
Maintenance has to be carried out by the operator
in accordance with the manufacturer's prescriptions
shown here below.
|
1 695 106 642
2010-12-22
6.2.1
Standard
Maintenance
DIN 51502-CLP
ISO 34-98-CC
Clean the mechanical moving parts, spray
them with nebulized oil or cherosene and lube
ISO VG 32
with appropriate grease
Remove the condensate from the filter assem-
bly.
Check oil level in the oil nebulizer.
Check transmission belt tensioning in order to
avoid its sliding.
Check the oil level in the gearbox and keep it
always between minimum and maximum level.

Change oil in the oil nebulizer.

6.2.2
1. Turn left the red button placed in the lower part of
the water separator.
2. Remove the accumulated condense by pressing the
same button.
3. Turn back in previous position the red button placed
in the lower part of the water separator.
6.2.3
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
3. Top up oil (see lube table).
6.2.4
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
3. Discharge oil and dispose it (see chap. 7.3).
4. Top up with new oil (see lube table).
Maintenance intervals
Condensate removal
Nebulizer oil refill
Change oil in the oil nebulizer
x
x
x
x
x
x