Troubleshooting

General remarks

The digital power sources are equipped with an intelligent safety system. This means
that apart from the fuse for the coolant pump, it has been possible to dispense with
fuses entirely. After a possible malfunction or error has been remedied, the power source
can be put back into normal operation again without any fuses having to be changed.
Displayed service
If any error message that is not described here appears on the displays, then the fault is
codes
one that can only be put right by a service technician. Make a note of the error message
shown in the display, and of the serial number and configuration of the power source,
and get in touch with our after-sales service, giving them a detailed description of the
error.
tP1 | xxx, tP2 | xxx, tP3 | xxx, tP4 | xxx, tP5 | xxx, tP6 | xxx
Cause:
Remedy:
tS1 | xxx, tS2 | xxx, tS3 | xxx
Cause:
Remedy:
tSt | xxx
Cause:
Remedy:
Err | 051
Cause:
Remedy:
Err | 052
Cause:
Remedy:
Warning! An electric shock can be fatal. Before opening up the machine
-
Switch the mains switch "OFF"
-
Unplug the machine from the mains
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-
Using a suitable measuring instrument, check to make sure that electrical-
ly charged components (e.g. capacitors) have been discharged
Caution! Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
earthing (grounding) the housing and must NOT be replaced by any other
screws that do not provide a reliable PE conductor connection.
Over-temperature in the primary circuit of the power source
Allow the power source to cool down
Over-temperature in the secondary circuit of the power source
Allow the power source to cool down
Over-temperature in the control circuit
Allow the power source to cool down
Mains undervoltage: The mains voltage has dropped below the tolerance
range (see chapter "Technical data")
Check the mains voltage
Mains overvoltage: The mains voltage has risen above the tolerance range
(see chapter "Technical data")
Check the mains voltage