Before Putting The Power Source Into Service; Safety; Utilisation For Intended Purpose Only; Machine Set-Up Regulations - Fronius TransTig 2200 Instructions De Service

Masquer les pouces Voir aussi pour TransTig 2200:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Before putting the power source into service

Safety

The power source may ONLY be used for TIG welding and rod electrode (MMA) welding.
Utilisation for
intended purpose
Utilisation for any other purpose, or in any other manner, shall be deemed to be "not in
only
accordance with the intended purpose". The manufacturer shall not be liable for any
damage resulting from such improper use.
Utilisation in accordance with the "intended purpose" also comprises
-
-
The power source is tested to "Degree of protection IP23", meaning:
Machine set-up
-
regulations
-
The venting duct is a very important safety feature. When choosing the machine locati-
on, make sure that it is possible for the cooling air to enter and exit unhindered through
the louvres on the front and back of the machine. Any electroconductive metallic dust
(e.g. from grinding work) must not be allowed to get sucked into the machine.

Mains connection

The equipment is designed to run on the mains voltage given on the respective rating
plates. If your version of the machine does not come with pre-fitted mains cable and
plug, these must be fitted in accordance with your national regulations and standards.
For details of the fuse protection of the mains lead, please see the Technical Data.
Generator-
The power sources MW 1700 / 2200, TT 2200 are generator-compatible, provided that
powered operati-
the maximum apparent power delivered by the generator is at least 10 kVA.
on (MW 1700 /
2200, TT 2200)
Warning! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and
completely understood all of the following documents:
-
these Operating Instructions
-
all "Operating Instructions" for the system components, especially the
"Safety rules"
following all the instructions given in this manual
performing all stipulated inspection and servicing work.
Protection against penetration by solid foreign bodies with diameters Ø 12.5 mm
(.49 in.)
Protection against direct sprays of water up to 60° from vertical
Warning! A machine that topples over or falls from its stand can easily kill
someone. Place equipment on an even, firm floor and ensure it remains stable.
Note! Inadequately dimensioned electrical installations can cause serious
damage. The mains lead, and its fuse protection, must be dimensioned accor-
dingly. The technical data shown on the rating plate shall apply.
Note! The voltage delivered by the generator must NEVER fall below or exceed
the mains voltage tolerance range. Details of the mains voltage tolerance are
given in the section headed "Technical data".