Displayed service
no | IGn
codes
(continued)
Cause:
Remedy:
Cause:
Remedy:
Err | IP
Cause:
Remedy:
Err | bPS
Cause:
Remedy:
dSP | Axx, dSP | Cxx, dSP | Exx, dSP | Sy, dSP | nSy
Cause:
Remedy:
no | Arc
Cause:
Remedy:
no | H2O
Cause:
Remedy:
hot | H2O
Cause:
Remedy:
-St | oP- (where the power source is being operated with a robot interface or a
field bus)
Cause:
Remedy:
"Ignition time-out" function is active: No current started flowing before the
end of the time specified in the set-up menu. The safety cut-out of the
power source has tripped.
Press the torch trigger repeatedly; clean the surface of the workpiece.
Err | PE
The earth fault current watchdog has tripped the power source safety cut-
out.
Switch off the power source, wait for 10 seconds and then switch it on
again. If you have tried this several times and the error keeps occurring,
contact After-Sales Service.
Primary overcurrent
Contact After-Sales Service
Fault in power module
Contact After-Sales Service
Fault in central control and regulation unit
Contact After-Sales Service
Arc break
Press the torch trigger repeatedly; clean the surface of the workpiece
Cooling unit flow watchdog has tripped
Check the cooling unit; if necessary, top up the coolant and/or vent the
water flow hose as described in "Putting the cooling unit into service"
Thermostat on cooling unit has tripped
Wait until the end of the cooling phase, i.e. until "Hot | H2O" is no longer
displayed. ROB 5000 or field bus coupler for robot control: Before resu-
ming welding, initialise the "Source error reset" signal.
Robot not ready
Initialise "Robot ready" signal, initialise "Source error reset" signal (N.B.
"Source error reset" only available in conjunction with ROB 5000 and field
bus coupler for robot control)