Tig Set-Up Parameters; Accessing - Fronius TransTig 2200 Instructions De Service

Masquer les pouces Voir aussi pour TransTig 2200:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TIG set-up parameters:

Accessing

1.
2.
3.
Important! The first parameter to be displayed is always the one that was the last to be
selected the last time the set-up menu was accessed.
Selecting and
1.
altering the set-
2.
up parameter
Saving and
1.
exiting
Available set-up
"Min." and "max." are used for setting ranges that differ according to power source.
parameters
tAC
Tacking - Duration of the pulsed welding current at the start of tacking
unit
setting range
factory setting
Important! The tacking function is only available for the TIG-DC welding process.
"ON" position
Value 0.1 - 9.9 s
"OFF" position
Please see the section headed "TIG welding" for a description of the tacking function.
Press the "Mode" button (1) to select either 2-step mode (2) or 4-step mode (3)
(2)
(3)
(1)
While pressing and holding the "Mode" button (1), press the parameter selection
button (8).
The first set-up parameter is displayed (e.g. "C-C")
Select the desired set-up parameter with the parameter selection button(s).
Alter the value of the set-up parameter with the adjusting dial
Press the "Mode" button (1)
s
OFF / 0.1 - 9.9 / ON
OFF
The pulsed welding current remains in effect until the end of the
tacking operation
The pre-set time begins with the upslope phase. After the end of the
pre-set time period, welding continues at constant amperage; any
pulsing parameters that have been set are available.
The tacking function is deactivated
+
37
(8)

Publicité

Table des Matières
loading

Table des Matières