TIG welding

Safety

1.

Tooling up

2.
3.
4.
5.
6.
Important! Instead of a control plug, the JobMaster TIG welding torch has a plug for the
standardised LocalNet connection socket.
6.
7.
8.
When using a TIG welding torch with an integral gas connector:
9.
10. Tighten the swivel nut
Only when using a water-cooled torch and cooling unit:
11. Plug in the welding torch water connectors to the water flow (black) and return (red)
12. Plug in the mains plug
Warning! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and
completely understood all of the following documents:
-
these Operating Instructions
-
all "Operating Instructions" for the system components, especially the
"Safety rules"
Warning! An electric shock can be fatal. If the machine is plugged into the
mains electricity supply during installation, there is a high risk of very serious
injury and damage. Only carry out work on the machine when
-
the mains switch is in the "OFF" position,
-
the machine is unplugged from the mains.
Switch the mains switch "OFF"
Unplug the machine from the mains
Plug the grounding (earthing) cable into the "plus" current socket and twist it to
fasten it
Use the other end of the grounding (earthing) cable to establish a connection to the
workpiece
Plug the welding cable of the TIG torch into the "minus" current socket and twist it
clockwise to latch it into place
Plug the control plug of the welding torch into the torch control connection and twist
it to fasten it
Connect up the JobMaster TIG welding torch to the LocalNet connection socket
Caution! Risk of damage from high frequencies. Do not use the JobMaster
TIG welding torch with a LocalNet distributor.
Tool up the welding torch (see the instruction manual for the torch)
Screw the pressure regulator onto the gas cylinder and tighten it
On the rear of the power source, connect the pressure regulator to the shielding gas
connection socket using the gas hose
connections on the cooling unit.
25