Chapitre 7 Chargement De Données; Chargement De Banques De Sons (Cd-Rom) - Roland XV-5080 Mode D'emploi

Table des Matières

Publicité

Chapitre 7 Chargement de données
Chargement de banques de
sons (CD-ROM)
Essayons à présent de charger une banque de sons (série
L-CDX optionnelle, par exemple) dans le XV-5080 et de jouer
certains sons. Pour utiliser des banques de sons via le
XV-5080, vous devez disposer d'un lecteur de CD-ROM SCSI
(CDR-88RW-2 optionnel) et de barrettes mémoire SIMM.
* Vous devez disposer d'au-moins 16 Mo de mémoire
supplémentaire (32 Mo ou plus recommandés).
Vous pouvez également charger les banques de sons du
CD-ROM AKAI S1000/3000 (p. 187).
Version française de la section suivante en page 183.
Installing the SIMM (Memory
Module)
Loading commercial sampler libraries into the XV-5080
requires installation of a SIMM memory module. The XV-
5080 is equipped with two slots for SIMMs, allowing you to
expand memory capacity by 128 MB (with two 64-megabyte
SIMMs installed).
SIMMs for use with the XV-5080 must match the
following specifications.
Number of pins: 72
Access time:
60 ns or lower
Access protocol: FPM or EDO
Voltage:
5 V
Capacity:
64 MB/32 MB/16 MB (can be mixed)
*Both parity and non-parity are supported.
SIMM height: 36 mm or less
Cautions When Installing SIMM
To avoid the risk of damage to internal components that can
be caused by static electricity, please carefully observe the
following whenever you handle the board.
• Before you touch the board, always first grasp a metal
object (such as a water pipe), so you are sure that any
static electricity you might have been carrying has been
discharged.
• When handling the board, grasp it only by its edges.
Avoid touching any of the electronic components or
connectors.
• Save the bag in which the board was originally shipped,
and put the board back into it whenever you need to
store or transport it.
Use a Philips screwdriver that is suitable for the size of the
screw. If an unsuitable screwdriver is used, the head of the
screw may be stripped.
To remove a screw, rotate the screwdriver counter-clockwise.
To tighten the screws, rotate the screwdriver clockwise.
fig.07-001.e
dévisser
visser
• Be careful not to cut your hands on the edges of the
opening while removing the cover.
• When adding SIMMs, remove only the specified screws.
• Be careful that the screws you remove do not drop into
the interior of the XV-5080.
• Do not touch any of the printed circuit pathways or
connection terminals.
• Never use excessive force when installing a circuit
board. If it doesn't fit properly on the first attempt,
remove the board and try again.
• When circuit board installation is complete, double-
check your work.
• Do not leave the cover removed. Be sure to reattach it
after the SIMM has been installed.
181

Publicité

Table des Matières
loading

Table des Matières