Télécharger Imprimer la page

1745-Slot X Drive Array - Drive Erase Operation Completed; 1746-Slot X Drive Array - Unsupported Storage Connection Detected; 1747-Slot X Drive Array - Unsupported Array Configuration Detected - HP ProLiant Manuel

Manuel de résolution des problèmes des serveurs
Masquer les pouces Voir aussi pour ProLiant:

Publicité

Action : Aucune action requise

1745-Slot X Drive Array - Drive Erase Operation Completed...

...The following disk drive(s) have been erased and will remain offline until hot-replaced or re-enabled
by the Array Configuration Utility: (suivi d'une liste de disques)
Bips sonores : Aucun
Cause possible : L'opération d'effacement de disque s'est correctement terminée et les disques sont
maintenus dans un état hors ligne pour s'assurer qu'ils restent vierges jusqu'à leur réactivation par
l'utilisateur.
Action : Remplacez chaque disque dans la liste ou réactivez chaque disque dans la liste à l'aide d'une
des méthodes suivantes :
Utilisez l'utilitaire ACU (Array Configuration Utility)
configuration de module RAID) à la page
Effectuez un retrait et une réinstallation à chaud (disques durs hot-plug uniquement).

1746-Slot X Drive Array - Unsupported Storage Connection Detected...

...SAS connection via expander is not supported on this controller model. Access to all storage has been
disabled. Upgrade controller or detach the expander based storage connections.
Bips sonores : Aucun
Cause possible : Le contrôleur ou la version du microprogramme ne prend pas en charge le boîtier de
disque connecté.
Action : Mettez à niveau le contrôleur ou déconnectez les connexions de stockage d'extension.

1747-Slot X Drive Array - Unsupported Array Configuration Detected...

...Suivi de l'une des possibles raisons, notamment les suivantes : * More logical drives are configured
than this controller can support when the memory module is detached.* One or more logical drives are
configured in positions that this controller does not support when the memory module is detached.* One
or more logical drives are configured for RAID fault tolerance level(s) that are not supported when the
memory module is detached.* Configuration information indicates one or more hard drives are located
in drive bays that are inaccessible when the memory module is detached.* Capacity Expansion
operations are pending but cannot continue because the Array Accelerator memory module has been
detached.* Drive Erase operations are pending but cannot be completed because the Array Accelerator
memory module has been detached.ALL logical drives have been disabled. To avoid data loss, re-attach
drives to original controller or upgrade controller. To discard all data and create a new configuration,
run the Array Configuration Utility.
Bips sonores : Aucun
Causes possibles :
Le module mémoire d'accélérateur RAID a été retiré ou est défectueux.
Les disques ont été déplacés vers un contrôleur qui ne dispose pas d'un module mémoire
d'accélérateur RAID relié.
Action : Reliez un module mémoire d'accélérateur RAID à ce contrôleur, ou déplacez les disques vers
le contrôleur d'origine. Si des opérations d'extension de capacité sont en attente, vérifiez que le module
d'accélérateur RAID d'origine est connecté.
FRWW
(Array Configuration Utility (Utilitaire de
81) (tous types de disque).
Messages d'erreur POST et codes de bip 169

Publicité

loading