1- Drill six holes in the marked locations for the six screws.
IMEON 3.6
2- Place the wall plate against the surface and fix it with the appropriate screws
3- Fit and fix with screws the IMEON on the wall plate and verify that the inverter is fixed
.
securely

3.3 Electrical connection

WARNING: To prevent any risk of electric shock, make sure that the ground cable is correctly
connected to the earth ground before switching on and using the inverter.
Source
Designation
PV1 +
PV1 -
PV
PV2 +
PV2 -
Earth
N
Grid
L1
L2
L3
BAT +
Battery
BAT -
Earth
N
AC Output
L1
L2
L3
Earth
Earth
WARNING: These values are provided solely for guidance. It is necessary to calculate again the
cable cross section, according to the current and to the cable length.
Manuel d'installation / Installation guide IMEON Inverter – Rev B.5
Suggestion of cable
Connectors
for IMEON 3.6
A : + (MC4 type)
6mm² stranded cable
4mm² solid cable
A : - (MC4 type)
B : + (MC4 type)
B : - (MC4 type)
C : L1 (RST)
6mm² stranded cable
C : L2 (RST)
4mm² solid cable
C : L3 (RST)
C : N (RST)
C (RST)
F : POS +
16mm2 stranded cable 95mm2 stranded cable
F : NEG -
D : L1 (RST)
6mm² stranded cable
D : L2 (RST)
4mm² solid cable
D : L3 (RST)
D : N (RST)
D : Gnd (RST)
6mm² stranded cable
E : Earth
4mm² solid cable
IMEON 9.12
Suggestion of cable
for IMEON 9.212
6mm² stranded cable
4mm² solid cable
6mm² stranded cable
4mm² solid cable
6mm² stranded cable
4mm² solid cable