IMEON INVERTER
3.9.2 Load Connection for IMEON 9.12
Connect the phases L1 to «L», L2 to «1» and L3 to
«2».
Connect the neutral wire to the symbol « N »
Connect the Earth wire to the symbol «
2
3
Step 3: Make sure the wires are securely connected.
Step 4: Plug the RST Connector in the AC OUTPOUT
socket.
WARNING: Before plugin in the cable, make sure there is no load on the circuit connected to the
AC Output.
WARNING: AC Output cannot be connected in parrallel to another IMEON and should not be
connected to the grid.

3.10 Temperature sensor

In case the temperature sensor is used, it must be connected to the T.CAP terminal. The temperature
sensor must be placed in the center of the battery bank. When the temperature sensor is connected, the
temperature compensation is 5mV/°C.
Manuel d'installation / Installation guide IMEON Inverter – Rev B.5
»