3. Installation

3.1 Selecting Mounting Location

 Do not mount the inverter on flammable construction materials.
 Mount on a solid surface.
 IMEON may possibly be noisy during operation which would be uncomfortable if installed in a
living room area.
 The temperature may cause a reduction of power due to the excessive heating.
 Install the IMEON at eye level in order to allow the LCD display to be read at all times.
 Dusty conditions may impair the performance of this inverter.
 Do not switch IMEON on, if the temperature or the humidity are out of the authorized limits.
The ambient temperature should be between -20°C and +50°C and relative humidity should
FR
be between 0% and 90% to ensure optimal operation.
 For proper air circulation to dissipate heat, allow a clearance of approx. 50 cm to the side and
FR
EN
approx. 50 cm above and below the IMEON.
 For proper operation of this inverter, please use appropriate cables for grid connection.
For the appropriate functioning of this inverter, please use adapted cables cross- section (taking
into account the length of cables, the mode of installation, the impedances, currents and voltage).
 The recommended installation position (vertical) is to be adhered to.
 Installation must be adapted to the weight and the dimensions of the inverter.
 This inverter is designed with IP20 for indoor applications only.

3.2 Mounting Unit

WARNING: This inverter is heavy! Please be careful when removing it from the package.
 Choose an appropriate place of support.
 Wall fixation should be done with the proper screws so that the solar inverter can be easily
attached. After that, the device should be bolted on securely.
WARNING: Suitable for mounting on concrete or other non-combustible surface only! Take into
account a space for ventilation between the case and the wall.
58
IMEON INVERTER
IMEON 3.6
5 to 9 mm
Ø M5
Manuel d'installation / Installation guide IMEON Inverter – Rev B.5