Step 1: Open the circuit breaker in order to work safely on the installation.
Step 2: Remove insulation sleeve and connect wires according to polarities indicated on the terminal
block. Be sure to connect PE protective conductor (
3.9.1 Load Connection for IMEON 3.6
Connect the phase to the symbol « L »
Connect the neutral to the symbol « N »
FR
Connect the ground to the symbol «
FR
EN
2
3
Step 3: Make sure the wires are securely connected.
Step 4: Plug the RST Connector in the AC OUTPOUT
socket.
WARNING: Before plugin in the cable, make sure there is no load on the circuit connected to the
AC Output.
WARNING: AC Output cannot be connected in parrallel to another IMEON and should not be
connected to the grid.
68
IMEON INVERTER
Manuel d'installation / Installation guide IMEON Inverter – Rev B.5